ALD-6000 series mini small-power frequency converter:
Single-phase 220V / three-phase 380V models adopt IPM/PIM chips respectively, with high overall reliability.
It can output 150% torque at 1Hz, featuring high starting torque.
Built-in PID and simple PLC with strong anti-interference performance.
Compact size and easy installation. This upgraded model comes with richer functions and simpler operation. It is suitable for occasions with strict noise requirements to meet various control demands.
Input
Rated Voltage & Frequency: 380V/220V, 50Hz/60Hz
Allowable Voltage Working Range: Voltage fluctuation range ≤±20%; Voltage unbalance rate <3%; Frequency fluctuation tolerance <±5%
Output
Output Voltage: 0~380V / 0~220V
Output Frequency Range: 0.10~400.00Hz
Overload Capacity: 150% rated continuous current for 60 seconds; 200% rated instantaneous current for 1 second; 220% rated current instant trigger protection
Main Control Performance & Featured Functions
Control Mode: General V/F control, customized multi-point V/F curve programmable control
PWM Modulation Mode: Space voltage vector PWM modulation, flexible soft PWM modulation technology
Speed Regulation Ratio: 1:40
Starting Torque: 3.0Hz output over 145% rated torque under standard V/F mode; torque response ≤60ms
Frequency Accuracy: Digital setting deviation: ±0.02% of maximum frequency; analog setting deviation: ±0.1% of maximum frequency
Frequency Resolution: Digital setting resolution: 0.01Hz; analog resolution: 0.05% of rated maximum frequency
Torque Boost Mode: Automatic torque dynamic boost / manual fixed torque boost, adjustable range 0.0%~20.0%
V/F Curve Selection: 20 groups optional curves including linear characteristic curve, fan pump square curve, user-defined multi-segment V/F curve
Acceleration & Deceleration Curve: Linear acceleration curve, S-type acceleration curve dual mode; maximum configurable acceleration/deceleration time up to 60 minutes
DC Braking Function: Adjustable braking startup frequency range (0.0Hz to upper frequency limit); braking duration adjustable from 0.0s~30.0s; braking current proportion 0%~150% rated motor current
AVR Automatic Voltage Regulation: Real-time output voltage stabilization under grid voltage fluctuation condition
Slip Compensation Function: Dynamic slip difference compensation for load variation, stabilize motor operating speed
Automatic Current Limiting: Intelligent current restraint during acceleration and stable operation, avoid frequent overcurrent fault tripping
Overvoltage Stall Protection: Active bus voltage limitation in deceleration process, prevent overvoltage shutdown fault
Momentary Power Failure Ride-through: Short voltage dip tolerance, maintain continuous operation without sudden tripping
Over-modulation Control: Over-modulation algorithm above fundamental frequency, promote high-speed motor output torque
Customized Individual Functions
Timer & Counter Module: Built-in independent timing unit and pulse counter, support timing startup/shutdown and external pulse statistical control
Built-in PLC & Multi-speed Operation: Realize multi-step fixed speed switching via internal logic PLC and control terminals
PID Closed-loop Control: Dedicated constant-pressure water supply PID algorithm preset, dual sleep mode for water pump energy-saving operation
Operation Functions
Operation Command Channel: Panel button control, terminal hardwire control, serial communication control three switching modes
Frequency Reference Channel: Digital set value, analog voltage input, analog current input, pulse signal, serial port, multi-speed terminal multi-channel selection
Frequency Combination Superposition: Multiple frequency sources superimpose output to realize compound speed adjustment logic
Operation Panel
Display Mode: Digital LED panel, support display of 24 types of running parameters
Button Permission Lock: Partial function button lockable, prevent field personnel misoperation parameter modification
Protection System
Protection Items: Total 19 built-in protection functions including optional phase loss protection, overcurrent, under-voltage, module overheat, overload, output short-circuit, external fault protection
Ambient Application Conditions
Installation Site: Indoor installation only; prohibit direct sunlight, dusty environment, corrosive gas, flammable medium, oil mist, steam, dripping water and salt mist atmosphere
Altitude Derating Rule: Power derate 10% per 1000 meters elevation when altitude exceeds 1000m
Operating Ambient Temperature: Standard working temperature -10℃~+40℃; power derating mandatory within 40℃~50℃ ambient temperature
Relative Humidity: 5%~95%RH, non-condensing indoor environment
Vibration Resistance Index: Bearing vibration less than 5.9m/s² (0.6g)
Storage Temperature Range: -40℃~+70℃
Structural Specifications
Protection Grade: IP20
Cooling Mode: Forced air cooling, intelligent fan automatic start-stop control
Every unit passes full power-on aging test before delivery. Remote parameter debugging and online technical troubleshooting are available, with exclusive technical support for bulk orders. We support bulk export shipment and OEM customization, and the whole machine enjoys standard warranty. Wearing parts such as cooling fans can be supplied separately.
Model positioning: It is specially developed for light-load energy-saving conditions of water pumps and fans. It is not applicable to equipment with heavy load impact, frequent forward-reverse rotation and high-precision closed-loop speed regulation. For such working conditions, it is recommended to upgrade to ALD550 or ALD3000 series.